As the content of the CFI-I exam is changing from time to time, you may feel anxious that it seems too hard to know the changes. Now, all complicate tasks have been done by our experts. They have rich experience in predicating the CFI-I exam. Then you are advised to purchase the study materials on our websites. Also, you can begin to prepare the CFI-I Exam. You are advised to finish all exercises of our CFI-I preparation questions and pass the exam by the first attempt very easily.

NFPA CFI-I Exam Syllabus Topics:

TopicDetails
Topic 1
  • Occupancy Types: This section tests the abilities of exam-takers to assess fire and life safety systems for different occupancy types, including assembly, educational, and healthcare facilities.
Topic 2
  • Administration: This section of the exam measures the skills of Fire Inspectors and covers the preparation of inspection reports, identifying the need for permits, and recognizing when plan reviews are required. It also involves investigating complaints, identifying applicable codes, and participating in legal proceedings. One key skill measured is communicating findings clearly in written reports.
Topic 3
  • Storage, Handling, & Use of Hazardous Substances and Materials: This module measures the skills of Fire Inspectors and includes recognizing hazardous conditions in equipment, processes, and operations.
Topic 4
  • Fire Protection Systems & Equipment: This section evaluates the skills of Fire Safety Technicians and focuses on determining the operational readiness of fire suppression systems, alarm systems, and portable fire extinguishers.

>> CFI-I Reliable Test Preparation <<

NFPA CFI-I Pass Guarantee, CFI-I Test Questions Pdf

We have three packages of the CFI-I study materials: the PDF, Software and APP online and each one of them has its respect and different advantages. So you can choose as you like accoding to your study interest and hobbies. We strongly advise you to purchase all three packages of the CFI-I Exam Questions. And the prices of our CFI-I learning guide are quite favourable so that you absolutely can afford for them.

NFPA Certified Fire Inspector I (CFI-1) Sample Questions (Q76-Q81):

NEW QUESTION # 76
The authorization to issue permits is granted by the

  • A. Fire Inspection Handbook.
  • B. authority having jurisdiction.
  • C. NFPA 101, Life Safety Code.
  • D. state legislature.

Answer: B

Explanation:
The authority having jurisdiction (AHJ) is the entity responsible for enforcing codes, standards, and regulations, including the authorization to issue permits.
The AHJ is defined as the organization, office, or individual responsible for approving plans, issuing permits, and ensuring compliance.
While state legislatures (A) may create laws, the actual enforcement and issuance of permits are delegated to the AHJ.
Fire Inspection Handbooks (C) and NFPA 101 (D) are reference tools but do not directly grant authority.
Reference:
NFPA 1, Fire Code, Section 3.2.2: Defines the AHJ's role and responsibilities.
NFPA 101: Acknowledges the AHJ as the enforcement body.


NEW QUESTION # 77
A high-hazard occupancy less than 200 ft² (18.6 m) in size, and with an occupant load not exceeding three, requires a second means of egress when the travel distance is greater than:

  • A. 15 ft (4.5 m)
  • B. 20 ft (6 m)
  • C. 10 ft (3 m)
  • D. 25 ft (7.6 m)

Answer: B

Explanation:
According to NFPA 101, Life Safety Code, Section 7.4.1, travel distance requirements determine when a second means of egress is necessary for small high-hazard occupancies:
For high-hazard occupancies less than 200 ft² with an occupant load of 3 or fewer, a second means of egress is required if the travel distance exceeds 20 ft (6 m).
This distance allows safe evacuation while minimizing exposure to hazardous conditions.
10 ft (A) and 15 ft (B): These distances are too restrictive based on NFPA 101.
25 ft (D): This exceeds the allowable limit.
Reference:
NFPA 101, Section 7.4.1: Means of egress requirements for small high-hazard occupancies.


NEW QUESTION # 78
What is the minimum diameter allowed for piping serving fire hydrants on private fire service mains?

  • A. 8 in. (203.2 mm)
  • B. 10 in. (254 mm)
  • C. 6 in. (152.4 mm)
  • D. 4 in. (101.6 mm)

Answer: C

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Fire Hydrant Piping Diameter:
Per NFPA 24 (Standard for the Installation of Private Fire Service Mains and Their Appurtenances), Section 5.2.1, the minimum diameter for piping serving fire hydrants on private fire service mains is 6 inches (152.4 mm).
Why 6 Inches is Required:
A minimum 6-inch pipe ensures sufficient water flow and pressure to meet firefighting demands.
Other Options Explained:
Option A (4 in): Too small; insufficient for hydrant water supply.
Option C (8 in) and Option D (10 in): Acceptable but exceed the minimum requirement.
Summary:
The minimum diameter for piping serving fire hydrants on private fire service mains is 6 inches (152.4 mm).


NEW QUESTION # 79
Which one of the following is a primary reason for issuing a permit?

  • A. To meet fire insurance requirements
  • B. To make the jurisdiction aware of potentially hazardous situations or conditions
  • C. To establish the economic feasibility of a project
  • D. To allow the requester to meet less restrictive code requirements

Answer: B

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Purpose of Permits:
Permits are issued primarily to ensure the jurisdiction (Authority Having Jurisdiction - AHJ) is aware of potentially hazardous situations or conditions and can enforce compliance with fire and safety codes.
Permits also provide an opportunity to inspect operations, processes, or structures to ensure safety.
NFPA References:
According to NFPA 1 (Fire Code), permits are required for activities that could pose risks, such as hazardous materials, fire protection system installations, and occupancy changes.
Other Options Explained:
Option A (To meet fire insurance requirements): Permits are not issued for insurance purposes, although compliance may indirectly affect insurance.
Option C (Less restrictive code requirements): Permits are not for bypassing codes.
Option D (Economic feasibility): Economic factors are unrelated to the permitting process.
Summary:
Permits are issued to make the jurisdiction aware of potentially hazardous situations or conditions and ensure compliance with fire safety regulations.


NEW QUESTION # 80
The fire resistance rating of a separation extending 10 ft (3050 mm) from a set of stairs shall not be required to exceed 1 hour where openings have a minimum of what fire protection rating?

  • A. 2 hour
  • B. 1 hour
  • C. ½ hour
  • D. 1 ½ hour

Answer: C

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Fire Resistance and Stair Separation:
According to NFPA 101 (Life Safety Code), Section 7.2.2.5, where a fire-rated separation extends 10 feet from a stair enclosure, the separation fire resistance does not need to exceed 1 hour if the openings have a ½-hour fire protection rating.
Why ½ Hour is Acceptable:
Openings with a ½-hour fire protection rating are sufficient to limit fire spread in lower-risk scenarios.
This exception applies to areas where the separation is minimal but still provides adequate protection to occupants using the stairway.
Other Options Explained:
Option A (2 hour): Not required for this scenario.
Option C (1 hour): The wall may be 1 hour, but the openings need only ½ hour.
Option D (1 ½ hour): Exceeds the requirements.
Summary:
Openings must have a minimum ½-hour fire protection rating where the fire resistance-rated separation extends 10 feet from a set of stairs.


NEW QUESTION # 81
......

There is always a fear of losing the CFI-I exam and this causes you may loss your money and waste the time. There is no such issue if you study our CFI-I exam questions. Your money and exam attempt is bound to award you a sure and definite success if you study with our CFI-I Study Guide to prapare for the exam. According to our data, our pass rate of the CFI-I practice engine is high as 98% to 100%. So if you choose our CFI-I learning quiz, you will pass for sure.